IviumSoft
Boosting Productivity in Electrochemical Research
Improve your Efficiency
IviumSoft is designed for the electrochemist and features all standard electrochemical and corrosion techniques: LSV, CV, transient techniques (CA, CP), corrosion techniques (Eoc, polarization, Tafel plot, galvanic corrosion), electroanalysis techniques (SWV, DPV, AC voltammetry, AC detection, pulse builder) and impedance (E and I controlled, and potential/current scan).
IviumSoft Advanced Features:
- Additional Functions in Advanced Mode: Allows electrochemistry experts to fully control the instrument.
- Abundant Data Analysis Tools: Includes peak finding, curve fitting, corrosion rate analysis, solar cell reporting and equivalent circuit evaluation.
IviumSoft integrated applications include:
- IviumSoft:
- CycliScan:
- MC Mode:
- IviLAB: Advanced and versatile data plotting for all your battery data, for all your channels, real time, with your choice of graphs and representation, charge-discharge • capacity vs. cycle nr. • EIS fit • charge efficiency • etc.
- Batch Mode: Using Batch Mode, the operator can automate complex measurement sequences, and interface to external equipment for process automation.
IviumSoft Suite Integrated applications:
IviumSoft Special functions:
Automatic current ranging
When desired, the user can instruct the potentiostat to automatically select the optimal current range setting. For this functionality all current ranges are available, including the hi-sensitivity current ranges.
Apply wrt OCP
The measurement potentials are defined relative to “Open Cell Potential”. Before the measurement starts, the OCP is determined in a zero-current configuration.
Analog inputs
The available analog inputs from the peripheral port may be recorded simultaneously with the primary results. The results are visualized graphically, and stored with the primary data.
Pulse generator
A continuously repeating pulse can be applied to the cell with variable period and duty cycle; intended as a tool to treat the electrode without data being measured.
Pretreatment
Up to 5 levels may be defined to condition the electrode before the actual measurement starts. The E/I values during “Pretreatment” are recorded and stored with the primary data.
Ohmic drop compensation
Manual or automatic Ohmic drop compensation
Current interrupt
Direct method that allows the user to determine the IR-drop of the electrochemical system via the current interrupt method (can only be used when Current Interrupt Module is available)
Signal view
The current and potential transients are shown in an oscilloscope type screen. Under dc-conditions, the E/I signals can be inspected for the presence of specific noise elements. During ac-techniques, the quality of the perturbing and resulting sine-waves is visualized. For each data point these traces are stored with the primary data and can be (re)viewed after completion of the experiment.